M&E Consultant London:
Low-Carbon MEP Design
Mesh Energy is an independent M&E and MEP consultant for London projects, from listed Mayfair townhouses to new homes on tight Knightsbridge plots. We design low-carbon heating, cooling, ventilation, electrical and renewable systems from RIBA Stage 0 to 7. We also write the London Plan energy statements that planning officers expect to see.
What does an
M&E consultant do on a London project?
An M&E consultant designs a building's mechanical and electrical systems: heating, cooling, ventilation, hot water, power and lighting. In London, the job also means fitting those systems into tight plots and listed fabric, and proving they meet London Plan carbon targets at planning. MEP design adds the public health services to the same package.
On a London scheme, our M&E and MEP work covers:
- Mechanical design: heating, cooling and mechanical ventilation with heat recovery
- Electrical design: power, lighting and renewable integration
- Heat pumps (air source and ground source) and solar PV
- London Plan energy statements and energy hierarchy calculations
- Overheating analysis and dynamic thermal modelling
- BIM coordination and clash detection in Revit

What does the London Plan mean for your M&E design?
The current London Plan (2021) requires major developments to be net zero carbon. At least 35% of the carbon reduction beyond Part L 2021 must happen on site. The rest can be offset through a payment to the borough. Your M&E design is what delivers that on-site reduction.
The Greater London Authority (GLA, London's regional government) asks major schemes to follow a four-step energy hierarchy:
- Be Lean: use less energy through fabric and efficiency. This alone must deliver at least 10% on homes and 15% on non-residential space.
- Be Clean: supply energy efficiently, including connecting to heat networks where available.
- Be Green: maximise on-site renewables such as heat pumps and solar PV.
- Be Seen: monitor and report energy performance after completion.
We write the energy statement and design the systems that meet it, so the numbers in your planning submission match the building you actually build.
Which London projects has Mesh worked on?
Our London work ranges from a Grade II listed gallery in Mayfair to five new townhouses in Knightsbridge. Both projects needed services that fit tight, sensitive spaces without compromising the building.
Sadie Coles HQ, Savile Row, Mayfair
The brief: a six-storey Grade II listed Georgian townhouse, dating from the 1730s, restored as a flagship contemporary art gallery. The programme was fixed: nine months from planning approval to opening in time for the Frieze Art Fair.
Our role: we developed the full MEP building services strategy, from concept through to detailed design. Dynamic thermal modelling of different occupancy scenarios let us size heating and cooling for each gallery individually. Services run concealed in void spaces, so they don't interrupt the architecture or the hang. External plant was positioned to meet strict planning limits on number, size and visibility. Actuated rooflights in the glazed lantern purge warm air, cutting reliance on active cooling.
Result: each gallery is controlled to its own occupancy, and the building performed well at its opening event of around 800 guests. Read the Sadie Coles HQ case study
Lancelot Place, Knightsbridge
The brief: five new townhouses on very narrow plots near Harrods, with three storeys below ground.
Our role: we delivered a full M&E building services design and updated the London Plan energy compliance statement. BIM Level 2 modelling was a key requirement, and we used it to coordinate every service in a very constrained footprint. There was no room for air source heat pumps, so we designed a ground source heat pump system with boreholes instead.
Result: a low-carbon heating solution that works within the site's space limits. Read the Lancelot Place case study.

Who leads our London M&E work?
Dan Grammer-Taylor leads Mesh's M&E team as M&E Team Lead. Before joining Mesh, Dan designed mechanical and electrical systems for manufacturers, contractors and consultancies, on homes, shops, hotels and stadiums. That means he understands a design from the client's, the installer's and the supplier's point of view.
At Mesh, Dan designs renewable energy systems and low-energy mechanical ventilation in Revit and AutoCAD.
"On a London site, space is the constraint everything else has to work around. If we model the services in 3D from day one, the plant fits, the planning officer is happy and nothing gets redesigned on site."
Dan Grammer-Taylor, M&E Team Lead, Mesh Energy
Why choose Mesh as your M&E consultant in London?
Our M&E engineers and building performance consultants work as one team. We model how a building will actually perform before we size the systems that serve it. That avoids oversized plant, which matters on London sites where every square metre of plant space costs floor area.
Mesh has been a certified B Corporation since 2021. Our memberships and accreditations include the Institution of Mechanical Engineers (IMechE), RIBA, the AECB and BRE.
We're based in Farnham, Surrey, around an hour by train from London Waterloo, and our team visits London sites throughout design and construction.
When should you bring in an
M&E consultant?
As early as possible, ideally before planning. On a London major development, the energy statement is part of the planning application, so the M&E strategy has to exist before you submit. Bringing us in at concept stage means the plant space, risers and renewables are designed into the scheme, not squeezed in afterwards.

Frequently asked questions
What is the difference between M&E and MEP?
M&E covers mechanical and electrical services: heating, cooling, ventilation, power and lighting. MEP adds the public health services to the same design package. Mesh provides both, so one consultant coordinates every service in the building.
Do you need a London office to work on London projects?
No. Most of our London design work happens in shared 3D models and online design team meetings. Our team visits site at the key stages, and our Farnham office is around an hour from central London.
Do you write London Plan energy statements?
Yes. We prepare energy statements that follow the GLA's Be Lean, Be Clean, Be Green, Be Seen hierarchy, and we design the M&E systems that deliver the carbon savings the statement promises.
Can heat pumps work on a tight London site?
Often, yes, but the right type depends on the site. At Lancelot Place there was no space for air source units, so we designed a ground source system with boreholes instead.
Which RIBA stages do you cover?
All of them, from Stage 0 strategic advice through to Stage 7 building in use. Most London clients appoint us at Stage 1 or 2, before the planning submission.
Talk to us about your London project
Tell us about your scheme, whether it's a listed refurbishment, a new build or a retrofit, and we'll come back with how we'd approach the M&E design.
Call 01420 481573, email info@mesh-energy.com, or send us your project details.
Working in Surrey? See our M&E consultant Surrey page.
Latest Insights